Details - fields
The Details level contains the following steps:
Readings
Hourly summarized readings
Daily summarized readings
Monthly summarized readings
Readings step
Field
Description
Measurement point
Displays the measurement point.
Occupancy value
Indicates whether the location is occupied.
The occupancy value can be:
0: not occupied
1: occupied
Null: no information received
For more information, see Occupancy measurement.
Passive occupancy
Indicates whether a location is passively occupied:
0: not passively occupied
1: passively occupied
empty: not measured
Pause reason
Displays the reason why a measurement point's occupancy status is put on Pause. This is a read-only field that can only be set by the Data Engine. Its values can be:
Connector inactive
Update next polling/event
Outside working hours
By including the Pause status, the relevant readings can also be viewed.
Person count
The values in this field can either be:
a digit / number: the actual occupancy value
empty: the sensoring system cannot count occupancy
For more information, see Occupancy measurement.
People in (cum.)
Displays the (cumulative) value of the inflow of people.
* 
This field only works for primary measurement points.
For more information, see How people flow works.
People out (cum.)
Displays the (cumulative) value of the outflow of people.
* 
This field only works for primary measurement points.
The values are registered for secondary measurment points, but these are not taken into account by the primary measurement point.
For more information, see How people flow works.
Reading date/time
Displays the sensoring system’s last reading date/time.
Normalized date/time reading
Displays the data engine’s last reading date/time in the time zone of the location linked to your measurement point.
Previous normalized date/time reading
Displays the data engine's normalized reading date/time before last.
Occupancy status
Displays the status of occupancy of the measurement point: Inactive, Pause, Immeasurable, Not occupied, Idle, Reservation imminent and Occupied.
Occupancy status change date-time
Displays the date/time of the last occupancy status change.
Previous occupancy status
Displays the status before the current status.
Within office hours
Yes indicates that the readings of the measurement point are taken during office hours. (Based on the calendar linked to the measurement point).
Person
Displays the person who occupies the location.
* 
Only if this was actually measured. Most sensoring systems measure values anonymously.
Location reserved
Yes indicates that the location was reserved.
Reservation
Displays the reservation that is active during reading time.
No show
Yes indicates that the measurement point experienced a 'No show' event.
Time saving from 'no show'
Displays the net time savings as a result of making a space available by detecting a 'no show'.
Early departure
Yes indicates that the measurement point experienced an 'Early departure' event.
Time saving from 'early departure'
Displays the net time savings as a result of making a space available by detecting an 'early departure'.
Maximum capacity (No.) - [NrOfPeopleCapacity]
Displays the maximum number of people the reservation unit can accommodate. The value is either taken from the measurement point, or from the linked location.
Reserved capacity
Displays the number of people for whom the location was reserved.
Battery status (voltage)
Displays the battery indication (voltage) received from the connector. The value indicates the status of the sensor's power supply.
If multiple sensors are linked to the measurement point, the lowest battery voltage is returned.
Light intensity (lux)
Displays the luminous intensity or lux (lx) received from the connector.
Carbon dioxide (ppm)
Displays the carbon dioxide level received from the connector. The measurement point's carbon dioxide level is given in parts per million (ppm).
Humidity (%)
Displays the humidity percentage received from the connector.
Noise (dB)
Displays the loudness level received from the connector. The measurement point's loudness level is given in decibel (dB).
Temperature (degrees)
Displays the temperature received from the connector. The measurement point's temperature is given in degrees Celsius or Fahrenheit, which is determined by the sensoring system.
Radon (pCi/L)
Displays the reading for Radon in picocuries per liter (pCi/L).
* 
One pCi/L equals 37 Bq/m3. If a sensor is measuring Bq/m, the connector needs to convert this value to pCi/L, the unit the Planon application is expecting.
PM2.5
Displays the indoor air quality readings of particles less than 2,5 µm in diameter. The value is given in µg/m3. If there are no particles measured, the value is Null.
PM10
Displays the indoor air quality readings of particles less than 10 µm in diameter. The value is given in µg/m3. If there are no particles measured, the value is Null.
Free field 1/3 for vendor specific readings
Displays any vendor specific values collected from the sensoring system. See also Sensoring system data > free fields.
Error code
Displays the error code that is published by the connector when encountering an error situation for the measurement point (not applicable for API).
System feedback
It displays an error message if the measurement point is Immeasurable. When monitoring is enabled, this field displays all data exchange (response) collected by the data engine.
Free measurement field 1/10
Free fields made available for capturing numeric values, e.g. number of particles in a given time frame. This data must be supplied by the sensoring system. Because they are numeric values, they can be summarized and used in analysis.