Sensor - fields
Field
Description
Measurement point
Select a measurement point from the list to which you want to link a sensor.
Sensor ID 1 – 5
Enter a sensor ID to uniquely identify a sensor. You can have a maximum of 5 IDs per sensor.
* 
The sensor system used determines which Sensor ID fields will be used for identification.
The combination of these 5 fields will render the sensor ID. It is not mandatory to use all 5 fields.
Sensor type
Select the sensor type from the picklist. This list must be consistent with your specific sensor system.
Secondary sensor?
Indicates whether the sensor serves a secondary role. If Yes, the sensor is used to correct the primary sensors. For example, the combination of people counting sensors (primary role) and motion sensors (secondary role).
Comment
Enter additional information if necessary.
Start date
Enter a start date for sensor activation.
End date
Enter an end date for sensor activation.
* 
The start date and end date are used for synchronization. Sensors with an invalid date are excluded from the synchronization run.